Title 18 - Unified Development Ordinance
18.435 Outdoor Lighting
18.435.090 Auto Dealer Lighting
-
A.Lighting for automobile dealerships shall be limited to non-adjustable, vertical mount, precise cut-off fixtures with flat lenses mounted horizontally to grade. The maximum allowable height for light poles shall be 24 feet, including pole base. A lighting plan, including photometrics, shall be submitted as part of the final development plan. The permitted light levels are as follows:
|
Maximum average maintained (footcandles) |
Maximum allowable illuminance |
Average to minimum ratio (maximum) |
Maximum to minimum ratio (maximum) |
|
|---|---|---|---|---|
| Vehicle display areas | 40 fc | 50 fc | 6:1 | 20:1 |
| All other Vehicle Areas | 5 fc | N/A | 6:1 | 20:1 |
-
B.The maximum light temperature is 4000K.
-
C.House side shields shall be provided on all perimeter parking lot lighting fixtures.
(History: Ord. No. ZRR-3447 §10, 2024)
Effective on: 1/1/1901