Title 16 - Buildings and Construction
16.110 Residential Code for One- & Two-Family Dwellings
- 16.110.100 2018 Residential Code - Adoption
- 16.110.R101.1
- 16.110.R102.5
- 16.110.R101.2
- 16.110.R101.4
- 16.110.R103
- 16.110.R201.5
- 16.110.R301.2(1)
- 16.110.R302.7
- 16.110.R302.13
- 16.110.R303.4
- 16.110.R306.5
- 16.110.R309.6
- 16.110.R310.1
- 16.110.R310.7
- 16.110.R313 One- and Two-Family Dwellings (Deleted)
- 16.110.R315.1 One- and Two-Family Dwellings (Deleted)
- 16.110.R317.1.1 One- And Two-Family Dwellings (Deleted)
- 16.110.R318.1.2 One- And Two-Family Dwellings (Deleted)
- 16.110.R319.2
- 16.110.R326.1
- 16.110.R328
- 16.110.R401.2
- 16.110.R405.1
- 16.110.R506.3
- 16.110.R506.4
- 16.110.R602.6
- 16.110.R703.2
- 16.110.R703.3.1.1
- 16.110.N1101.5 One- And Two-Family Dwellings (Deleted)
- 16.110.N1101.8 One- And Two-Family Dwellings (Deleted)
- 16.110.N1101.12
- 16.110.N1102.4
- 16.110.N1103.3.3
- 16.110.N1103.3.5 One- And Two-Family Dwellings (Deleted)
- 16.110.N1103.3.7 One- And Two-Family Dwellings (Deleted)
- 16.110.N.1103.9 One- AND Two-Family Dwellings (Deleted)
- 16.110.N1103.5.1.1
- 16.110.N1104.1
- 16.110.N1106.4
- 16.110.N1112
- 16.110.P2503.3
- 16.110.E3901.12 One- And Two-Family Dwellings (Deleted)
- 16.110.E3902.2
- 16.110.E3902.5
- 16.110.E3902.10 One- And Two-Family Dwellings (Deleted)
- 16.110.E3902.13 One- And Two-Family Dwellings (Deleted)
- 16.110.E4002.14 One- And Two-Family Dwellings (Deleted)
- 16.110.E3902.16
- 16.110.M1502.4.2
- 16.110.AV
16.110.100 2018 Residential Code - Adoption
For the purpose of new construction of single-family residences that (i) are less than 2,500 square feet of total livable floor area, or gross floor area minus garages and basements, in size, and (ii) are constructed on each such residence’s own separate lot or parcel with its own individual legal description:
The 2018 International Residential Code, as published by the International Code Council, Inc., is hereby adopted by reference, save and except such parts or portions thereof as are specifically deleted, added or changed in the City Code. At least one copy shall be marked “Official Copy as Incorporated by Ordinance No. BC-3513” and filed with the City Clerk for inspection by the public during reasonable business hours, with all sections or portions thereof intended to be deleted, added or changed clearly marked to show any deletions, additions or changes.
Note: Any reference in OPMC Chapter 16.110 to the “International Residential Code” or to the “International Residential Code for One- and Two-Family Dwellings” is only intended to refer to the 2018 International Residential Code. Any deletion, addition or change set forth in OPMC Chapter 16.110 shall only apply to the 2018 International Residential Code and shall not be interpreted to delete, add to or change any section or provision of any Residential Code adopted by OPMC Chapter 16.310.
(History: Ord. No. BC-3499, §49, 2026, Ord. BC-3286 §44, 2020; Ord. BC-2936 §28, 2012; BC-2635 §49, 2007; BC-2459 §33, 2004; BC-2237 §2, 2001)
Effective on: 1/1/1901
16.110.R101.1
Section R101.1 of the 2018 International Residential Code is hereby amended to read as follows:
(History: Ord. No. BC-3513, §50, 2026; Ord. No. BC-3286 §45, 2020; Ord. No. BC-2936 §29, 2012; Ord. No. BC-2635 §50, 2007)
Effective on: 1/1/1901
16.110.R102.5
Section R102.5 of the 2018 International Residential Code is hereby amended to read as follows:
(History: Ord. No. BC-3513, §51, 2026; Ord. No. BC-3286 §48, 2020; Ord. No. BC-2936 §31, 2012; Ord. No. BC-2635 §52, 2007; Ord. No. BC-2459 §35, 2004; Ord. No. BC-2237 §2, 2001)
Effective on: 1/1/1901
16.110.R101.2
Section R101.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
(History: Ord. BC-3286 §46, 2020; Ord. BC-2936 §168, 2012; BC-2635 §51, 2007; BC-2459 §34, 2004)
R101.2 Scope.
The provisions of this Code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height.
Exception: The following shall be permitted to be constructed in accordance with this Code:
- 1.Live/work units located in townhouses with five or fewer non-residential workers or employees and complying with the limitations in Section 419 of the International Building Code.
Exception: Section 419.5 of the International Building Code does not apply if the live/work unit complies with the occupant limitations in exception 1.
- 2.Owner-occupied lodging houses with five or fewer guestrooms.
- 3.A care facility with five or fewer persons receiving care within a dwelling unit.
- 4.A care facility with five or fewer persons receiving medical care within a dwelling unit.
- 5.A care facility for five or fewer persons receiving care that are within a single-family dwelling.
(History: Ord. BC-3286 §46, 2020)
Effective on: 1/1/1901
16.110.R101.4
Section R101.4 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R101.4 Administration.
The administrative and enforcement provisions for this Code shall be those provisions found in the International Building Code Sections 103 through 115 except as amended in OPMC 16.100 et seq.
(History: Ord. BC-3286 §47, 2020; Ord. BC-2936 §30, 2012; BC-2635 §51, 2007; BC-2459 §34, 2004)
Effective on: 1/1/1901
16.110.R103
Sections R103 through R114 of the International Residential Code for One- and Two-Family Dwellings are hereby deleted. (See Violations, Notices and Orders, Unsafe Structures and Equipment, Emergency Measures, and Demolition provisions set forth in OPMC Title 7.)
(History: Ord. BC-3286 §49, 2020; Ord. BC-2936 §32, 2012; BC-2635 §53, 2007; BC-2459 §36, 2004; BC-2237 §2, 2001)
Effective on: 1/1/1901
16.110.R201.5
Section R201.5 of the International Residential Code for One- and Two-Family Dwellings is hereby added.
R201.5 Interpretations of definitions.
For purposes of interpretation of the definitions of Building, Existing in Section R202, the phrase “a legal building permit” shall be interpreted to mean one for which a certificate of occupancy has been issued.
(History: Ord. BC-3286 §50, 2020)
Effective on: 1/1/1901
16.110.R301.2(1)
Table No. R301.2(1) of Section 301 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
| Table R301.2(1) Climatic and Geographic Design Criteria | |||||||||||||
| GROUND SNOW LOAD | WIND DESIGN | SEISMIC DESIGN CATEGORYf | SUBJECT TO DAMAGE FROM | WINTER DESIGN TEMPe | ICE BARRIER UNDERLAYMENT REQUIREDh | FLOOD HAZARDSg | AIR FREEZING INDEXi | MEAN ANNUAL TEMPj | |||||
| Speedd (mph) | Topographic effectsk |
Special Wind Region |
Windborne Debris Zone |
||||||||||
| Weatheringa | Frost line depthb | Termitec | |||||||||||
| 20 PSF | 115 | No | No | No | A | Severe | 36” |
Moderate to Heavy |
6° F | Yes |
09/14/1977, 08/03/2009 |
1500 or Less |
54.8° F |
| Manual J Design Criteria | |||||||
| Elevation | Latitude |
Winter heating |
Summer cooling |
Altitude correction factor |
Indoor design temp |
Design temp Cooling |
Heating temp difference |
| 1096 ft | 39 | 10° F | 10° F | 0.97 | Heating 72° F | 75° F | 62° F |
|
Cooling temp difference |
Wind velocity heating |
Wind velocity cooling |
Coincident wet bulb |
Daily range |
Wind humidity |
Summer humidity |
|
| 18° F | 15 MPH | 7.5 MPH | 76° F | M | - |
46@ 50% RH |
|
|
For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. |
|
Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, “negligible,” “moderate” or “severe” for concrete as determined from Figure R301.2(4). The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 OR C652. |
|
Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. |
|
The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. |
|
The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(5)A]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. |
|
The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. [Also see Figure R301.2(1).] |
|
The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. |
|
The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction’s entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study. |
|
In accordance with Section sR905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with “YES.” Otherwise, the jurisdiction shall fill in this part of the table with “NO.” |
|
The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32oF).” |
|
The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32oF).” |
|
In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with “YES.” Otherwise, the jurisdiction shall indicate “NO” in this part of the table. |
|
In accordance with Figure R301.2(5)A, where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with “YES” and identify any specific requirements. Otherwise, the jurisdiction shall indicate “NO” in this part of the table. |
|
In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate “NO” in this part of the table. |
|
The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. |
|
The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figure R301.2(6). |
(History: Ord. BC-3286 §51, 2020; Ord. BC-2936 §33, 2012; BC-2635 §55, 2007; BC-2459 §38, 2004; BC-2237 §2, 2001; Source or prior law: 16.05.120; BC-2013 §20, 97)
Effective on: 1/1/1901
16.110.R302.7
Section R302.7 of the 2018 International Residential Code is hereby amended to read as follows:
(History: Ord. No. BC-3513, §52, 2026)
Effective on: 1/1/1901
16.110.R302.13
Section R302.13 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R302.13 Fire Protection of Floors
Floor assemblies that are not required elsewhere in this code to be fire-resistance rated, shall be provided with a ½-inch gypsum wallboard membrane, ⅝-inch wood structural panel membrane, or equivalent on the underside of the floor framing member. Penetrations or openings for ducts, vents, electrical outlets, lighting, devices, luminaires, wires, speakers, drainage, piping and similar openings or penetrations shall be permitted.
Exceptions:
- 1.Floor assemblies located directly over a space protected by automatic fire sprinklers. The sprinklers are permitted to be installed on a ¾-inch domestic water line.
- 2.Floor assemblies located directly over a crawl space.
- 3.Portions of floor assemblies shall be permitted to be unprotected where complying with the following:
3.1. The aggregate area of the unprotected portions does not exceed 80 square feet per story.
3.2. Fireblocking in accordance with Section R302.11.1 is installed along the perimeter of the unprotected portion from the remainder of the floor assembly.
- 4.Wood floor assemblies using dimension lumber or structural composite lumber equal to or greater than 2-inch by 10-inch nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance.
(History: Ord. BC-3286 §52, 2020)
Effective on: 1/1/1901
16.110.R303.4
Section R303.4 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R303.4 Mechanical Ventilation.
Where the air infiltration rate of a dwelling unit is less than three (3) air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50 Pa) in accordance with Section N1102.4.1.2, the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1505.4.
(History: Ord. BC-3286 §53, 2020; Ord. BC-2936 §36, 2012)
Effective on: 1/1/1901
16.110.R306.5
Section R306.5 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R306.5 New Single-Family Dwellings Toilet Facilities.
Toilet facilities shall be provided within 500 feet (measured from the property line adjacent to the street for platted subdivisions along the public way) for all new single-family dwellings starting from the time of the first footing inspection until facilities are available in the dwelling. If the facilities are not located on the job site, the location of the required facilities shall be posted on the job site or other certification provided to the Building Official to verify the availability of toilet facilities. The facilities on the site shall be removed prior to issuance of a Temporary Certificate of Occupancy.
(History: Ord. BC-3286 §54, 2020; Ord. BC-2936 §37, 2012; BC-2635 §57, 2007; BC-2459 §39, 2004; BC-2237 §2, 2001; Source or prior law: 16.08.170; BC-2013 §41, 97)
Effective on: 1/1/1901
16.110.R309.6
Section R309.6 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R309.6 Residential Driveways.
Residential concrete and asphalt driveway slabs shall be a minimum of four inches (4”) thick. The driveway shall have a constant slope so as to avoid ponding of water. The slope shall be away from the house or building or drain by means approved by the Building Official.
(History: Ord. BC-3286 §55, 2020; Ord. BC-2936 §38, 2012; BC-2635 §58, 2007; BC-2459 §40 & 187, 2004; BC-2237 §2, 2001; Source or prior law: 16.05.130; BC-2013 §21, 97)
Effective on: 1/1/1901
16.110.R310.1
Section R310.1 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R310.1 Emergency Escape and Rescue Required.
Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way.
Exceptions:
- 1.Dwellings for which the building permit for the initial construction of that dwelling was issued prior to January 1, 2001, are exempt from the above requirement for subsequent basement remodels; provided, however, that exemption shall only apply if the basement has not been expanded subsequent to January 1, 2001, or that basement does not at any time contain any sleeping areas; conversion of any habitable area to a sleeping area at any time will trigger the emergency escape and rescue requirements set forth above. All currently existing openings that provide for emergency escape and rescue, regardless of whether or not they comply with the above escape and rescue requirements, cannot be removed or altered without bringing the basement into full compliance with the minimum requirements of this Section, regardless of when building permits for the dwelling were issued.
- 2.Storm shelters and basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet.
- 3.Where the dwelling or townhouse is equipped with an automatic sprinkler system installed in accordance with Section P2904, sleeping rooms in basements shall not be required to have emergency escape and rescue openings provided that the basement has the following:
3.1 One means of egress complying with Section R311 and one emergency escape and rescue opening.
3.2 Two means of egress complying with Section R311.
R310.1.1 Operational constraints and opening control devices. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools or special knowledge. Window opening control devices on windows serving as a required emergency escape and rescue opening shall comply with ASTM F2090.
(History: Ord. BC-3286 §56, 2020; Ord. BC-2936 §39, 2012; BC-2635 §59, 2007; BC-2459 §41, 2004; BC-2341 §1, 2002)
Effective on: 1/1/1901
16.110.R310.7
Section R310.7 of the 2018 International Residential Code is hereby added to read as follows:
(History: Ord. No. BC-3513, §53, 2026)
Effective on: 1/1/1901
16.110.R313 One- and Two-Family Dwellings (Deleted)
Section R313 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §57, 2020; Ord. BC-2936 §40, 2012)
Effective on: 1/1/1901
16.110.R315.1 One- and Two-Family Dwellings (Deleted)
Section R315 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286, §185, 2020)
Effective on: 1/1/1901
16.110.R317.1.1 One- And Two-Family Dwellings (Deleted)
Section R317.1.1of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §58, 2020)
Effective on: 1/1/1901
16.110.R318.1.2 One- And Two-Family Dwellings (Deleted)
Section R318.1.2 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §59, 2020)
Effective on: 1/1/1901
16.110.R319.2
Section R319.2 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R319.2 Illumination.
Single family dwellings shall have the ability to illuminate the address and numbers during the hours of darkness with a power source connected to the house electrical system or other approved source of illumination.
(History: Ord. BC-3286 §60, 2020; Ord. BC-2936 §42, 2012; BC-2635 §61, 2007; BC-2459 §43, 2004; BC-2237 §2, 2001; Source or prior law: 16.05.177.500 (part); BC-2143 §20, 98)
Effective on: 1/1/1901
16.110.R326.1
Section R.326.1 of the International Residential Code for One-and Two-Family Dwellings is hereby amended to read as follows:
R326.1 General.
The design and construction of pools and spas shall comply with appendix U.
(History: Ord. BC-3286 §61, 2020)
Effective on: 1/1/1901
16.110.R328
Section R328 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
Section R328
PHYSICAL SECURITY
R328.1 Purpose. The purpose of this Section is to establish minimum standards that incorporate physical security to make dwelling units resistant to unlawful entry.
R328.1.1 Scope. The provisions of this Section shall apply to all new structures and to additions and alterations made to existing buildings.
R328.2 Doors. Except for vehicular access doors, all exterior swinging doors of residential buildings and attached garages, including the doors leading from the garage area into the dwelling unit, shall comply with Sections R328.2.1 through R328.2.5 for the type of door installed.
R328.2.1 Wood doors. Where installed, exterior wood doors shall be of solid core construction such as high-density particleboard, solid wood, or wood block core with a minimum thickness of one and three-fourths inches (1 3/4”) at any point. Doors with panel inserts shall be solid wood. The panels shall be a minimum of one inch (1”) thick. The tapered portion of the panel that inserts into the groove of the door shall be a minimum of one-quarter inch (¼”) thick. The groove shall be a dado groove or applied molding construction. The groove shall be a minimum of one-half inch (½”) in depth.
R328.2.2 Steel doors. Where installed, exterior steel doors shall be a minimum thickness of 24 gauge.
R328.2.3 Fiberglass doors. Fiberglass doors shall have a minimum skin thickness of one-sixteenth inch (1/16”) and have reinforcement material at the location of the deadbolt.
R328.2.4 Double doors. Where installed, the inactive leaf of an exterior double door shall be provided with flush bolts having an engagement of not less than one inch into the head and threshold of the doorframe.
R328.2.5 Sliding doors. Where installed, exterior sliding doors shall comply with all of the following requirements:
- 1.Sliding door assemblies shall be installed to prevent the removal of the panels and the glazing from the exterior with the installation of shims or screws in the upper track.
- 2.All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frame’s exterior surface. The surface mounted bolt assembly shall be installed at the base of the door.
R328.3 Door frames. The exterior door frames shall be installed prior to a rough-in inspection. Door frames shall comply with Sections R328.3.1 through R328.3.3 for the type of assembly installed.
R328.3.1 Wood frames. Wood door frames shall comply with all of the following requirements:
- 1.All exterior door frames shall be set in frame openings constructed of double studding or equivalent construction, including garage doors, but excluding overhead doors. Door frames, including those with sidelights shall be reinforced in accordance with ASTM F476-14 Grade 40.
- 2.In wood framing, horizontal blocking shall be placed between studs at the door lock height for three (3) stud spaces or equivalent bracing on each side of the door opening.
R328.3.2 Steel frames. All exterior door frames shall be constructed of 18 gauge or heavier steel, and reinforced at the hinges and strikes. All steel frames shall be anchored to the wall in accordance with manufacturer specifications. Supporting wall structures shall consist of double studding or framing of equivalent strength. Frames shall be installed to eliminate tolerances inside the rough opening.
R328.3.3 Door jambs.
- 1.Door jambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve inches (12”) each side of the strike. Filler material shall consist of a solid wood block.
- 2.Door stops on wooden jambs for in-swinging doors shall be of one-piece construction. Jambs for all doors shall be constructed or protected so as to prevent violation of the strike.
R328.4 Door hardware. Exterior door hardware shall comply with Sections R328.4.1 through R328.4.6.
R328.4.1 Hinges. Hinges for exterior swinging doors shall comply with the following:
- 1.At least two (2) screws, three inches (3”) in length, penetrating at least one inch (1”) into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge.
- 2.Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior.
R328.4.2 Strike plates. Exterior door strike plates shall be a minimum of 18 gauge metal with four offset screw holes. Strike plates shall be attached to wood with not less than three inch (3”) screws, which shall have a minimum of one inch (1”) penetration into the nearest stud. Note: For side lighted units, refer to Section R328.4.6.
R328.4.3 Escutcheon plates. All exterior doors shall have escutcheon plates or wrap-around door channels installed around the lock protecting the door’s edge.
R328.4.4 Locks. Exterior doors shall be provided with a locking device complying with one of the following:
Single Cylinder Deadbolt shall have a minimum projection of one inch (1”). The deadbolt shall penetrate at least three-fourths inch (3/4”) into the strike receiving the projected bolt. The cylinder shall have a twist-resistant, tapered hardened steel cylinder guard. The cylinder shall have a minimum of five (5) pin tumblers, shall be connected to the inner portion of the lock by solid metal connecting screws at least one-fourth inch (1/4”) in diameter and two and one-fourth inches (2-1/4”) in length. Bolt assembly (bolt housing) unit shall be of single piece construction. All deadbolts shall meet ANSI grade 2 specifications.
R328.4.5 Entry vision and glazing. All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. The view may be provided by a door viewer having a field of view of not less than 180 degrees through windows or through view ports.
R328.4.6 Side lighted entry doors. Side light door units shall have framing of double stud construction or equivalent construction complying with Sections R328.3.1, R328.3.2 and R328.3.3. The doorframe that separates the door opening from the side light, whether on the latch side or the hinge side, shall be double stud construction or equivalent construction complying with Sections R328.3.1 and R328.3.2. Double stud construction or construction of equivalent strength shall exist between the glazing unit of the side light and wall structure of the dwelling.
R328.5 Street numbers. Street numbers shall comply with Section R321.1.
R328.6 Exterior Lighting. Exterior lighting shall comply with Sections R328.6.1 through R328.6.2.
R328.6.1 Front and street side exterior lighting. All front and street side door entrances should be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent), installed so that the light source is not readily accessible.
R328.6.2 Rear exterior lighting. Homes with windows or doors near ground level below eight feet (8’) on the rear side of the house shall be equipped with a minimum of one light outlet having 100 watt lighting (or energy efficient equivalent) and shall be of the flood light type. Those fixtures placed below eight feet (8’) shall be fixtures manufactured such that the light source is not readily accessible.
R328.7 Alternate materials and methods of construction. The provisions of this Section are not intended to prevent the use of any material or method of construction not specifically prescribed by this Section, provided any such alternate has been approved by the enforcing authority, nor is it the intention of this Section to exclude any sound method of structural design or analysis not specifically provided for in this Section. The materials, methods of construction, and structural design limitations provided for in this Section shall be used, unless the enforcing authority grants an exception.
The enforcing authority is authorized to approve any such alternate provided they find the proposed design, materials, and methods of work to be at least equivalent to those prescribed in this Section in quality, strength, effectiveness, burglary resistance, durability, and safety.
(History: Ord. BC-3286 §62, 2020; Ord. BC-2936 §43, 2012; BC-2635 §62, 2007; BC-2459 §44, 2004; BC-2318 §1, 2001; BC-2237 §2, 2001; Source or prior law: 16.05.177.100; BC-2143 §1, 98; 16.05.177.110; BC-2143 §2, 98; 16.05.177.200; BC-2143 §3, 98; 16.05.177.210; BC-2143 §4, 98; 16.05.177.220; BC-2143 §5, 98; 16.05.177.230; BC-2143 §6, 98; 16.05.177.240 (part); BC-2143 §7, 98; 16.05.177.250; BC-2143 §8, 98; 16.05.177.300; BC-2143 §9, 98; 16.05.177.310 (part); BC-2143 §10, 98; 16.05.177.320; BC-2143 §11, 98; 16.05.177.330; BC-2143 §12, 98; 16.05.177.400; BC-2143 §13, 98; 16.05.177.410; BC-2143 §14, 98; 16.05.177.420; BC-2143 §15, 98; 16.05.177.430 (part); BC-2143 §16, 98; 16.05.177.440 (part); BC-2143 §17, 98; 16.05.177.450; BC-2143 §18, 98; 16.05.177.460; BC-2143 §19, 98; 16.05.177.500; BC-2143 §20, 98; 16.05.177.610; BC-2143 §21, 98; 16.05.177.620; BC-2143 §22, 98; 16.05.177.800; BC-2143 §23, 98)
Effective on: 1/1/1901
16.110.R401.2
Section R401.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R401.2 Requirements.
R401.2 Requirements. Foundation construction shall be capable of accommodating all loads according to Section R301 and of transmitting the resulting loads to the supporting soil. Fill soils that support footings and foundations shall be designed, installed and tested in accordance with accepted engineering practice. Gravel fill used as footings for wood and precast concrete foundations shall comply with Section R403. Foundations that are designed in compliance with the Johnson County Foundation Guideline endorsed by the Johnson County Building Officials Association dated October 1, 2007 shall be considered as an approved alternative to compliance with this chapter.
R401.2.1 Design required. A design in accordance with accepted engineering practice shall be provided for concrete or masonry foundation walls when any of the conditions listed below exist.
- 1.Walls are subject to hydrostatic pressure from ground water.
- 2.Walls supporting more than 48 inches (48”) of unbalanced backfill that do not have permanent lateral support at the top and bottom.
- 3.Sites containing CH, MH, OL, or OH soils as identified in Table R405.1
- 4.Foundation walls exceeding ten feet (10’) in height, measured from the top of the wall to the bottom of the slab.
- 5.Lots identified on the subdivision grading plan as having more than six feet (6’) of fill or having a finished slope steeper than 4 horizontal to 1 vertical before grading.
- 6.Footings and foundations with existing fill soils below the footing level.
- 7.Sloping lots steeper than 4 to 1 before grading.
- 8.Lots where some footings will bear on soil and others will bear on rock.
- 9.Areas where problems have historically occurred.
- 10.Stepped footing and foundation walls.
R401.2.2 Continuous footing reinforcement. Continuous footings for basement foundation walls shall have minimum horizontal reinforcement consisting of not less than two No. 4 bars, uniformly spaced, located a minimum 3 inches (3”) clear from the bottom of the footing.
R401.2.3 Foundation anchorage. The spacing of anchor bolts or foundation anchor straps required by Section R403.1.6 shall be reduced to a maximum of 3 feet (3’) on center for basement foundation walls.
(History: Ord. BC-3286 §63, 2020; Ord. BC-2936 §44, 2012; BC-2635 §§63, 64 & 65, 2007; BC-2459 §§45, 47 & 48, 2004; BC-2237 §2, 2001)
Effective on: 1/1/1901
16.110.R405.1
Section R405.1 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R405.1 Concrete or Masonry Foundations.
Drains shall be provided around all concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or material shall be installed at or below the area to be protected and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend at least one foot (1’) beyond the outside edge of the footing and six inches (6”) above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper. Perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on a minimum of two inches (2”) of washed gravel or crushed rock at least one sieve size larger than the tile joint opening or perforation and covered with not less than six inches (6”) of the same material.
Exceptions:
- 1.A drainage system is not required when the foundation is installed on well-drained ground or sand-gravel mixture soils according to the Unified Soil Classification System, Group I Soils, as detailed in Table R405.1.
- 2.A filter membrane is not required where perforated drains are covered with at least eighteen inches (18”) of washed gravel or crushed rock.
- 3.For gravel or crushed stone drains a filter membrane is not required when the gravel or crushed stone extends at least eighteen inches (18”) above the top of the footing.
R405.1.1 Precast concrete foundation. Precast concrete foundation walls that retain earth and enclose habitable or useable space located below-grade that rest on crushed stone footings shall have a perforated drainage pipe installed below the base of the wall on either the interior or exterior side of the wall, at least one foot (1’) beyond the edge of the wall. If the exterior drainage pipe is used, an approved filter membrane material shall cover the pipe. The drainage system shall discharge into an approved sewer system or to daylight.
(History: Ord. BC-3286 §64, 2020; Ord. BC-2936 §45, 2012)
Effective on: 1/1/1901
16.110.R506.3
Section R506.3 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R506.3 Design Required.
A design in accordance with accepted engineering practice shall be provided for concrete floors when the limitations for fill material set forth in Section R506.2.1 are exceeded. Where applicable, a standard design approved by the City may be used in lieu of a design from the design professional.
(History:Ord. BC-3286 §65, 2020; Ord. BC-2936 §47, 2012; BC-2635 §66, 2007)
Effective on: 1/1/1901
16.110.R506.4
Section R506.4 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
R506.4 Basement Floor Slab Isolation.
Basement floor slabs shall be isolated from column pads, interior columns and interior bearing walls to facilitate differential movement. Nonbearing walls supported on basement floor slabs shall be provided with a minimum one inch (1”) expansion joint to facilitate differential movement between the floor slab and the floor framing above. Isolation and/or an expansion joint is not required within six inches (6”) of the exterior walls.
(History:Ord. BC-3286 §66, 2020; Ord. BC-2936 §48, 2012; BC-2635 §67, 2007)
Effective on: 1/1/1901
16.110.R602.6
Section R602.6 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R602.6 Drilling and Notching of Studs.
Drilling and notching of studs shall be in accordance with the following:
- 1.Notching. Any stud in an exterior wall or bearing partition may be cut or notched to a depth not exceeding twenty-five percent (25%) of its width. Studs in nonbearing partitions may be notched to a depth not to exceed forty percent (40%) of a single stud width.
- 2.Drilling. Any stud may be bored or drilled, provided that the diameter of the resulting hole is no more than sixty percent (60%) of the stud width, the edge of the hole is no more than five-eighths inch (5/8”) to the edge of the stud, and the hole is not located in the same section as a cut or notch. Studs located in exterior walls or bearing partitions drilled over forty percent (40%) and up to sixty percent (60%) shall also be doubled with no more than two successive doubled studs bored. See Figures R602.6(1) and R602.6(2).
Exception: Use of approved stud shoes is permitted when they are installed in accordance with the manufacturer’s recommendations.
R602.6.1 Drilling and notching of top plate. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than fifty percent (50%) of its width, a galvanized metal tie not less than 0.054 inch thick (16 ga) and one and one-half inches (1½”) wide shall be fastened across and to the plate at each side of the opening with not less than four 10d (0.148 inch diameter) nails having a minimum length of one and one-half inches (1½”) at each side or equivalent. The metal tie must extend a minimum of six inches (6”) past the opening. See Figure R602.6.1.
Exception: When the entire side of the wall with the notch or cut is covered by wood structural panel sheathing.
(History: Ord. BC-3286 §67, 2020; Ord. BC-2936 §49, 2012)
Effective on: 1/1/1901
16.110.R703.2
Section R703.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
R703.2 Water-resistive barrier.
One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other approved water-resistive barrier shall be applied over studs or sheathing of all exterior walls. No. 15 asphalt felt shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other approved materials shall be installed in accordance with the water-resistive barrier manufacturer’s installation instructions. The No. 15 asphalt felt or other approved water-resistive barrier material shall be continuous to the top of walls and terminated at the penetrations and building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1.
Exception: Omission of the water resistive barrier is permitted if both of the following exceptions are met:
- 1.In detached accessory buildings that are not a dwelling.
- 2.In detached accessory buildings that do not contain conditioned space.
(History: Ord. BC-3286 §68, 2020)
Effective on: 1/1/1901
16.110.R703.3.1.1
Section R703.3.1.1 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §69, 2020)
Effective on: 1/1/1901
16.110.N1101.5 One- And Two-Family Dwellings (Deleted)
Section N.1101.5 (R103.2) of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §70, 2020)
Effective on: 1/1/1901
16.110.N1101.8 One- And Two-Family Dwellings (Deleted)
Section N1101.8 (R103.2) of the 2012 International Residential Code for One- and Two- Family dwellings is hereby deleted.
(History: Ord. BC-2936 §50, 2012)
Effective on: 1/1/1901
16.110.N1101.12
Section N1101.12 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1101.12 (R303.3) Maintenance Information.
Maintenance instructions shall be furnished for equipment and systems that require preventative maintenance.
(History: Ord. BC-3286 §71, 2020)
Effective on: 1/1/1901
16.110.N1102.4
Section N1102.4 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1102.4 Air Leakage (Mandatory).
The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections N1102.4.1 through N1102.4.54.
N1102.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections N1102.4.1.1 and N1102.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contractions.
N1102.4.1.1 Installation. The components of the building thermal envelope as listed in Table N1102.4.1.1 shall be indicated in accordance with the manufacturer’s instructions and the criteria indicated in Table N1102.4.1.1, as applicable to the method of construction. Where required by the Code Official, an approved third party shall inspect all components and verify compliance.
N1102.4.1.2 Testing. Where required by the Code Official, the building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding five air changes per hour. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the Code Official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the Code Official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
- 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other infiltration control measures;
- 2.Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures;
- 3.Interior doors, where installed at the time of the test, shall be open;
- 4.Exterior or interior terminations for continuous ventilation systems shall be sealed;
- 5.Heating and cooling systems, if installed at the time of the test, shall be turned off; and
- 6.Supply and return registers, if installed at the time of the test, shall be fully open.
N1102.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace.
N1102.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more that 0.3 cfm per square foot, and swinging doors no more than 0.5 cfm per square foot, when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows, skylights and doors.
N1102.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
(History: Ord. BC-3286 §72, 2020; Ord. BC-2936 §52, 2012)
Effective on: 1/1/1901
16.110.N1103.3.3
Section N1103.3.3 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1103.3.3 (R403.3.3) Duct testing (Mandatory).
Where required by the Code Official, ducts shall be pressure tested to determine air leakage by one of the following methods:
- 1.Rough-in-test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. Registers shall be taped or otherwise sealed during the test.
- 2.Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test.
Exceptions:
- 1.A duct air-leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.
- 2.A duct air-leakage test shall not be required for ducts serving heat or energy recovery ventilators that are not integrated with ducts serving heating or cooling systems.
A written report of the results of the test shall be signed by the party conducting the test and provided to the building official.
(History: Ord. BC-3286 §73, 2020)
Effective on: 1/1/1901
16.110.N1103.3.5 One- And Two-Family Dwellings (Deleted)
Section N1103.3.5 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §74, 2020)
Effective on: 1/1/1901
16.110.N1103.3.7 One- And Two-Family Dwellings (Deleted)
Section N1103.3.7 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §75, 2020)
Effective on: 1/1/1901
16.110.N.1103.9 One- AND Two-Family Dwellings (Deleted)
Sections N1103.9, N1103.10, 1103.11, and 1103.12 of the International Residential Code for One- and Two-Family Dwellings are hereby deleted.
(History: Ord. BC-3286 §77, 2020)
Effective on: 1/1/1901
16.110.N1103.5.1.1
Section N1103.5.1.1 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1103.5.1.1 (R403.5.1.1) Circulation systems.
Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
(History: Ord. BC-3286 §76, 2020)
Effective on: 1/1/1901
16.110.N1104.1
Section N1104.1 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1104.1 Lighting Equipment.
Not less than 100 percent of the permanently installed recessed can lights and keyless fixtures shall contain only high-efficiency lamps.
N1104.1.1 Lighting equipment. Fuel gas systems shall not have continuous burning pilot lights.
(History: Ord. BC-3286 §78, 2020; Ord. BC-2936 §55, 2012)
Effective on: 1/1/1901
16.110.N1106.4
Section N1106.4 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
N1106.4 ERI-based compliance.
Compliance based on an ERI analysis requires that the rated design be shown to have an ERI less than or equal to the appropriate value of 68 when compared to the ERI reference design. Where on-site renewable energy is included for compliance using the ERI analysis of Section N1106.4, the building shall meet the mandatory requirements of Section 1106.2, and the building thermal envelope shall be greater than or equal to the levels of efficiency and SHGC in Table N1102.1.2 or Table N1102.1.4.
(History: Ord. BC-3286 §79, 2020)
Effective on: 1/1/1901
16.110.N1112
Section N1112 of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
SECTION N1112
LOCAL PRESCRIPTIVE COMPLIANCE ALTERNATIVE
N1112.1 General. The building thermal envelope shall comply with the requirements of Sections N1112.2 Through N1112.3, the installed equipment shall comply with Section N1112.4, and the lighting equipment shall comply with Section N1112.5.
N1112.2 Mandatory requirements. Compliance with this section requires that the provisions identified in Sections N1101.13 through N1104 indicated as “mandatory” and in section N1103.5.3 be met. The building thermal envelope shall be greater than or equal to the levels of efficiency and Solar Heat gain Coefficients in Table 402.1.1 or 402.1.3 of the 2009 International Energy Conservation Code.
Exceptions:
- 1.Supply and return ducts not completely inside the building thermal envelope shall be insulated to an R-value of not less than R-8.
- 2.Compliance with Tables N1102.1.2 and N1102.1.4 is not required.
N1112.3 Insulation and fenestration criteria. The building thermal envelope shall meet or exceed the requirements of Table N1112.1.
| TABLE N1112.1 | |||||||||
| Insultation and Fenestration Requirements by Componenta | |||||||||
|
FENESTRATION U-FACTORb |
SKYLIGHTb U-FACTOR |
GLAZE FENESTRATION SHGCb,c |
CEILING R-VALUE |
WOOD FRAME WALL R-VALUE |
MASS WALL R-VALUEg |
FLOOR R-VALUE |
BASEMENTc WALL R-VALUE & DEPTH |
SLABd R-VALUE & DEPTH |
CRAWL SPACEc WALL R-VALUE |
| 0.34 | 0.55 | 0.31 | R-49 | R-13 | 8/13 | 30 |
R-10/11, 3ft Below Grade Line |
10,2 ft | 10/13 |
- a.R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of the insulation, the installed R-value of the insulation shall be not less than the R-value specified in the table.
- b.The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
- c.“10/11 means R-10 continuous insulation on the interior or exterior of the home or R-11 cavity insulation on the interior of the basement wall.
- d.R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation R-value for slabs, as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slab.
- e.There are no SHGC requirements in the Marine Zone.
- f.Basement wall insulation shall not be required in warm-humid locations as defined by Figure N1101.10 and Table N1101.10.
- g.Mass walls shall be in accordance with Sections N1102.2.5. The second R-value applies where more than half of the insulation is on the interior of the mass wall.
N1112.4 Equipment efficiency rating. The buildings mechanical equipment shall meet or exceed the requirements in Table N1112.2
| TABLE N1112.2 | ||
| MINIMUM EQUIPMENT EFFICIENCY RATING BY COMPONENT | ||
| Furnace | Air Conditioner | Water Heater |
| 80% | 13 SEER | 62% |
N1112.5 Lighting equipment. Not less than 100 percent of the permanently installed recessed can lights and keyless fixtures shall contain only high-efficiency lamps.
(History: Ord. BC-3286 §80, 2020)
Effective on: 1/1/1901
16.110.P2503.3
Section P2503.3 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
P2503.3 Responsibility of Permittee.
The permit holder shall make the applicable test prescribed in Section 2503.5 through Section 2503.8 to determine compliance with the provisions of this Code. Test equipment, materials and labor shall be furnished by the permittee.
Exceptions:
- 1.The testing of the DWV rough plumbing system shall be done in accordance with Section P2503.5.1 when required by the Code Official.
- 2.The testing of the building sewer shall be done in accordance with Section P2503.4 when required by the Code Official.
- 3.The testing of the finished plumbing shall be done in accordance with Section P2503.5.2 when required by the Code Official.
- 4.The testing of the shower liner shall be done in accordance with Section P2503.6 when required by the Code Official.
- 5.The testing of the water supply piping shall be done in accordance with Section P2503.7 when required by the Code Official.
(History: Ord. BC-3286 §82, 2020)
Effective on: 1/1/1901
16.110.E3901.12 One- And Two-Family Dwellings (Deleted)
Section E3901.12 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §83, 2020)
Effective on: 1/1/1901
16.110.E3902.2
Section E3902.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
E3902.2 Garage and Accessory Building Receptacles.
125-volt, single-phase, 15- and 20-amphere receptacles installed in garages and grade-level portions of unfinished accessory buildings used for storage or work areas shall have ground-fault circuit-interrupter protection for personnel. [210.8(A)(2)].
Exception: A dedicated receptacle supplying a garage door opener, fire alarm, security system, sump pump, refrigerator, freezer or electric vehicle charger.
(History: Ord. BC-3286 §84, 2020; Ord. BC-2936 §57, 2012)
Effective on: 1/1/1901
16.110.E3902.5
Section E3902.5 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
E3902.5 Unfinished Basement Receptacles.
125-volt, single-phase, 15- and 20-ampere receptacles installed in unfinished basements shall have ground-fault circuit-interrupter protection for personnel. For purposes of this Section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms. [210.8(A)(5)].
Exception:
1. A dedicated receptacle supplying a garage door opener, fire alarm, security system, sump pump, refrigerator, freezer or electric vehicle charger.
(History: Ord. BC-3286 §85, 2020; Ord. BC-2936 §58, 2012)
Effective on: 1/1/1901
16.110.E3902.10 One- And Two-Family Dwellings (Deleted)
Section E3902.10 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §86, 2020)
Effective on: 1/1/1901
16.110.E3902.13 One- And Two-Family Dwellings (Deleted)
Section E3902.13 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §87, 2020)
Effective on: 1/1/1901
16.110.E4002.14 One- And Two-Family Dwellings (Deleted)
Section E4002.14 of the International Residential Code for One- and Two-Family Dwellings is hereby deleted.
(History: Ord. BC-3286 §89, 2020; Ord. BC-2936 §60, 2012)
Effective on: 1/1/1901
16.110.E3902.16
Section E3902.16 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
E3902.16 Arc-Fault Circuit-Interrupters.
BAll branch circuits that supply 120-volt, single phase 15- and 20-amphere receptacles installed in bedrooms shall be protected by any of the following: [210.12(A)]
- 1.A listed combination-type arc-fault circuit-interrupter, installed to provide protection of the entire branch circuit. [210.12(A)(1)]
- 2.A listed branch/feeder-type AFCI installed at the origin of the branch-circuit in combination with a listed outlet branch-circuit-type arc-fault circuit-interrupter installed at the first outlet box in the branch circuit shall be marked to indicate that it is the first outlet of the circuit. [210.12(A)(2)]
- 3.A listed supplemental arc-protection circuit breaker installed at the origin of the branch circuit in combination with a listed outlet branch-circuit-type arc-fault circuit-interrupter installed at the first outlet box on the branch circuit where all of the following conditions are met:
3.1. The branch-circuit wiring shall be continuous from the branch-circuit overcurrent device to the outlet branch-circuit arc-fault circuit interrupter.
3.2. The maximum length of the branch-circuit wiring from the branch-circuit overcurrent device to the first outlet shall not exceed 50 feet for 14AWG conductors and 70 feet for 12AWG conductors.
3.3 The first outlet box on the branch circuit shall be marked to indicate that it is the first outlet on the circuit. [210.12(A)(3)]
- 4.A listed outlet branch-circuit type arc-fault circuit-interrupter installed at the first outlet on the branch circuit in combination with a listed branch-circuit overcurrent protective device where all of the following conditions are met.
4.1. The branch-circuit wiring shall be continuous from the branch-circuit overcurrent device to the outlet branch-circuit arc-fault circuit interrupter.
4.2. The maximum length of the branch-circuit wiring from the branch-circuit overcurrent device to the first outlet shall not exceed 50 feet for 14AWG conductors and 70 feet for 12AWG conductors.
4.3 The first outlet box on the branch circuit shall be marked to indicate that it is the first outlet on the circuit.
4.4 The combination of the branch-circuit overcurrent device and outlet branch-circuit AFCI shall be identified as meeting the requirements for a system combination-type AFCI and shall be listed as such. [210.12(A)(4)]
- 5.Where metal outlet boxes and junction boxes and RMC, IMC, EMT, Type MC or steel-armored Type AC cables meeting the requirements of Section E3908.8, metal wireways or metal auxiliary gutters are installed for the portion of the branch circuit between the branch-circuit overcurrent device and the first outlet, a listed outlet branch-circuit type AFCI installed at the first outlet shall be considered as providing protection for the remaining portion of the branch circuit. [210.12(A)(5)]
- 6.Where a listed metal or nonmetallic conduit or tubing of Type MC cable is encased in not less than 2 inches of concrete for the portion of the branch circuit between the branch-circuit overcurrent device and the first outlet, a listed outlet branch-circuit-type AFCI installed at the first outlet shall be considered as providing protection for the remaining portion of the branch circuit [210.12(A)(6)]
Exception: AFCI protection is not required for individual branch circuits supplying a garage door opener, fire alarm, security system, sump pump, refrigerator, freezer or electric vehicle charger.
(History: Ord. BC-3286 §88, 2020)
Effective on: 1/1/1901
16.110.M1502.4.2
Section M1502.4.2 of the International Residential Code for One- and Two-Family Dwellings is hereby amended to read as follows:
M1502.4.2 Duct installation.
Exhaust ducts shall be supported at intervals not to exceed 12 feet and shall be secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Exhaust duct joints shall be sealed in accordance with Section M1601.4.1 and shall be mechanically fastened. Ducts shall not be joined with screws or similar fasteners that protrude more than ⅛ inch into the inside of the duct.
(History: Ord. BC-3286 §81, 2020)
Effective on: 1/1/1901
16.110.AV
Appendix V of the International Residential Code for One- and Two-Family Dwellings is hereby added to read as follows:
Appendix V Electric Vehicle-Ready Provisions--Detached One- and Two-Family Dwellings and Townhouses
APPENDIX V
ELECTRIC VEHICLE-READY PROVISIONS--DETACHED ONE- AND
TWO-FAMILY DWELLINGS AND TOWNHOUSES
This appendix is informative and is not part of the code.
____________________________________________________________________________________________________________________________________________________________________________________
User Note:
About this appendix: Appendix V provides guidance for the installation of Electric Vehicle-Ready construction in new Detached One- And Two-family Dwellings and Townhouses.
______________________________________________________________________________________________________________________________________________________________________________________________________________________
SECTION V101
SCOPE
V101.1 General. These provisions shall be applicable for new construction where electric vehicle-ready provisions are required.
SECTION V102
GENERAL DEFINITIONS:
V102.1 General. The following terms shall, for the purpose of the appendix, have the meaning shown herein.
ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors, and the Electric Vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the Electric Vehicle.
EV READY SPACE. A designated parking space which is provided with one 40-ampere, 208/240-volt dedicated branch circuit for EVSE servicing Electric Vehicles. The circuit shall terminate in a suitable termination point such as a receptacle, junction box, or an EVSE, and be located in close proximity to the proposed location of the EV parking spaces.
Effective on: 1/1/1901