Title 18 - Unified Development Ordinance

 

18.440 Signs

18.440.060 Regulations Applicable to Individual Sign Types

  1. A.
    Attached Signs.

Attached Signs

Sign Type

 Number Limit  Sign Area Limit  Miscellaneous
 Wall Sign  Per zoning district  Per zoning district 

 See 18.440.060.A.1 regarding 

Sign Design

 Painted Wall Sign  1, in lieu of 1 wall sign  10 s.f.  
 Projecting Sign   1, in lieu of 1 wall sign

Per zoning district-

same as wall sign area 

 Cannot extend above wall 

surface or more than 3 feet from 

wall surface

 Building Entry Sign Per zoning district  Per zoning district 

For multi-tenant buildings 

with an interior corridor 

 Ground Floor Tenant

Wall Sign

Per zoning district   Per zoning district

For multi-story, multi-tenant

buildings with separate

ground floor tenant entries 

 Under Canopy Sign

1 per business entry,

oriented toward

pedestrians 

 9 s.f. 

7-foot clearance required

above sidewalk 

 Roof Sign

 1 per building, in lieu

of 1 wall sign

Per zoning district-

same as wall sign area 

Cannot extend above

roofline.  Structural members 

concealed, except for channel

letter raceways 

 Neon Sign

Per zoning district,

in lieu of an allowed

attached sign

 Per sign area limit of

attached sign type

See 18.440.050.E regarding

Illumination 

 Incidential Sign Per zoning district  Per zoning district 

See 18.440.060.A.1 regarding

Sign Design 

    1. 1.
       Sign Design
      1. a.
        Wall Sign:
        1. 1.
          Shall have individual letters for the majority of the sign area. A cabinet sign shall provide push-through projections with at least ¾-inch relief.

 

Cabinet Sign - Letter Projections

 

 Drawing of a cabinet sign with letter projections
 Required letter projection for cabinet signs
          1. a.
            Secondary wall sign elements may be allowed as cabinet-type signs. A single rectangle drawn around all secondary sign elements shall be no more than 30% of the total wall sign area.
        1. 2.
          Shall not extend above the wall surface.
      1. b.
        Incidential Sign:
        1. 1.
          Non-illuminated.
        2. 2.
          Wall-mounted incidental signs are not subject to the height limits specified per zoning district below.
        3. 3.
          This provision shall not apply to existing multi-tenant buildings with previously approved sign criteria for all the tenant wall signs to be printed on a uniform sign band around the bulding.
  1. B.
    Detached Signs.

Detached Signs

Sign Type

 Number Limit  Sign Area Limit  Miscellaneous
 Monument Sign Per zoning district  Per zoning district

 See 18.440.060.B.1 

regarding Sign Design

 Parking Area Sign

1 per development

entry and at key

parking area

intersections

4 s.f. 5-foot height limit
Incidental Sign Per zoning district Per zoning district

See 18.440.060.B.1

regarding Sign Design

Internal Subdivision

Monument Sign

1 per entry to each

unique internal 

subdivision phase

6 s.f. 5-foot height limit
Kiosk

As approved by the

Planning Commission

per City regulations

20 s.f.

10-foot height limit. Digital

Display allowed.

(18.440.050.F)

Point-of-Activity Sign

2 in conjunction with

each customer 

interaction point

32 s.f.

8-foot height limit.

Oriented toward the 

vehicle or person being

served.  Digital display

allowed. (18.440.050.F)

Detached Canopy Sign

(canopy 200 s.f. or less)

1 per canopy fascia

and 2 fascia

maximum

9 s.f.

Cannot extend beyond

edge of canopy fascia

Detached Canopy Sign

(canopy over 200 s.f.)

1 per canopy fascia

and 3 fascia

maximum

Lesser of 10% of

canopy fascia or 20 

s.f.

Canot extend beyond

edge of canopy fascia.

Digial Display allowed.

(18.440.050.F)

Light Pole Banner Per zoning district.

See 18.440.060.B.1

regarding Sign Design

7-foot clearnace required.

See 18.440.060.B.1

regarding Sign Design.

Permanent Display for

Temporary Messages

Per zoning disctrict Per zoning district

See 18.440.060.B.1

regarding Sign Design

    1. 1.
      Sign Design
      1. a.
        Monument Sign:
        1. 1.

          The width of the sign base shall be a minimum of one-half the width of the widest part of the sign face.

        2. 2.

          The sign base shall consist of metal (rust and corrosion resistant) or a masonry or concrete substructure with an exterior consisting of durable masonry materials and include brick, split-face block, or natural or synthetic cementitious stone or brick. The sign base shall be composed of architectural features, forms, colors and materials consistent with the primary architectural elements and materials consistent with or used in the development or on the principal building.

          1. a.

            Alternative compatible, durable, materials may be approved by the Director or by the Planning Commission through the Final Development Plan approval process.

          2. b.

            Foam-backed products, such as EIFS or faux brick, wood, and/or other nondurable products shall not be used.

        3. 3.

          The sign base may be in a designated landscape or hardscape area or must otherwise be protected from ongoing lawn maintenance. It cannot be located in a paved area, such as a parking stall.

        4. 4.

           Shall not consist primarily of large, flat, backlit panels.

      2. b.

        Incidental Sign:

        1. 1.

          May be single-or double-sided.

        2. 2.

          Non-illuminated.

        3. 3.

          If post-mounted, the posts shall be stained or painted and finished with decorative caps.  The sign panel shall be mounted between the tow posts.

 

Incidental Sign

 

 Photo of an incidental sign amongst a parking lot and landscape
 Example of Incidental sign
        1. 4.
          In the case of vacant land, one sign facing each street frontage shall be allowed, provided that all such signs shall meet the size, height and setback requirements listed per zoning district below, and that signs located on the same property shall be separated by at least 200 feet.
      1. c.
        Light Pole Banners:
        1. 1.
          One sign permit shall be required for all of the banners in a development. A site plan shall be submitted with the permit application to identify all proposed locations.
        2. 2.
          Banners shall be periodically replaced to minimize fading, fraying, tearing, etc. A new sign permit shall not be required for replacement, unless the size, number, or locations of banners are proposed to change.
        3. 3.
          No more than two banners shall be allowed on each light pole. The sign area for a single light pole banner shall not exceed 20 s.f., with a limit of 20 s.f. per pole. Total light pole banner sign area for a site shall be calculated as 9 s.f. for every light pole.
      2. d.
        Permanent Display for Temporary Messages:  In conjunction with a monument sign, a permanent display for temporary messages is allowed subject to the following:
        1. 1.
          Display frame shall be removed when not in use unless installed in a permanent manner.
        2. 2.
          Frame shall be four-sided and shall not consist solely of two posts to display a banner. Provided, an alternative architectural or artistic design may be approved by the Director.
        3. 3.
          Frame shall be stained or painted.

 

Permanent Display for Temporary Messages

 

 Photo of a Permanent Display sign with temporary message
 Example of permanent display for temporary messages

 

(History:  Ord. No. ZRR-3300 §7, 2020; Ord. ZRR 3061 §2, 2015; ZRR 2427 §7, 2003)

Effective on: 1/1/1901