Title 18 - Unified Development Ordinance

 

18.435 Outdoor Lighting

 

18.435.050 Development and Performance Standards

Where provided, parking lot lighting, including building and pole mounted lighting is subject to the following standards:

 

  1. A.
    Residential zoning listed below and all Non-Residential Uses in a Residential District.

 

 Maximum light

temperature

 Maximum 

average

footcandles

Minimum

average

footcandles 

Average to

minimum ratio 

Maximum to

minimum ratio 

 4000K 2.0  1.0  <6:1  <20:1 
  1.  
    1. 1.
      Parking lot lighting mounting heights.
      1. a.
        Maximum height of the pole and fixture shall be no taller than 20 feet when measured from grade. Measurement shall include the pole base.

 

 

  1. B.
    Commercial and Industrial Uses

 

 Maximum light

temperature

 Maximum 

average

footcandles

Minimum

average

footcandles 

Average to

minimum ratio 

Maximum to

minimum ratio 

 4000K 3.0  1.0  <6:1  <20:1 
  1.  
    1. 1.
      Parking lot lighting mounting heights.
      1. a.
        Maximum height of the pole and fixture shall be no taller than 33 feet when measured from grade. Measurement shall include the pole base.

 

(History: Ord. No. ZRR-3447 §6, 2024)

Effective on: 1/1/1901