Title 18 - Unified Development Ordinance

 

18.220 RP-4 Planned Cluster Housing District

18.220.030 Height and Area Regulations

The maximum height of buildings, the minimum dimensions of lots and yards and the minimum site area per dwelling unit permitted on any lot shall be as follows, except as otherwise provided in 18.150 and 18.420:

  1. A.
    Maximum height:
    1. 1.
      Residential structures--two and one-half stories, not exceeding 35 feet.
    2. 2.
      Accessory structures and uses, other than non-residential structures--one story, not exceeding 20 feet and not exceeding the height of the residential structures.
  2. B.
    Minimum yard areas/setbacks:
    1. 1.
      Where a lot line abuts a street, the minimum setback for main structures shall be as follows:
      1. a.
        20 feet from thoroughfare; or
      2. b.
        10 feet from a super-collector, collector or any other street.
    2. 2.
      Each residential building shall provide a yard between the building and a property line of the project, other than a street line, of not less than 10 feet.
    3. 3.
      Each accessory building shall provide a yard between the building and the property line of the project, other than a street line, of not less than 7 feet.
    4. 4.
      There shall be a yard between buildings of not less than 12 feet.
    5. 5.
      For Infill or Redevelopment projects, the perimeter setback along a public street shall not be less than the average setback for residential uses along the same and facing block faces
  3. C.
    The minimum net site area per dwelling unit shall be 6,000 square feet.

(History: Ord. ZRR-2848 §11, 2010; ZRR-1725; ZRR-1637; ZRR-889 §18.14)

Effective on: 1/1/1901