Title 7 - Health and Sanitation
7.25 Property Maintenance
7.25.606.1 General.
Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, be available for public inspection in the office of the building operator or be posted in a publicly conspicuous location approved by the Code Official. The inspection and tests shall be performed at not less than the periodic intervals listed in Table 601.1.
| Table 606.1 Inspection and Test Intervals in “Months” |
|||||||||
|---|---|---|---|---|---|---|---|---|---|
| Periodic Inspections | Periodic Test | ||||||||
| Reference Section | Equipment Type | Category 1 | Category 3 | Category 5 | |||||
| Requirement | Interval | Requirement | Interval | Requirement | Interval | Requirement | Interval | ||
| 8.11.2 | Electric elevators | 8.11.2.1 | NA | 8.11.2.2 | 12 | N/A | N/A | 8.11.2.3 | 60 |
| 8.11.3 | Hydraulic elevators | 8.11.3.1 | NA | 8.11.3.2 | 12 | 8.11.3.3 | 8.11.3.4 | 60 | |
| 8.11.4 | Escalators and moving walks | 8.11.4.1 | NA | 8.11.4.2 | 12 | N/A | N/A | N/A | N/A |
| 8.11.5.1 | Sidewalk elevators | 8.11.2.1, 8.11.3.1 | NA | 8.11.2.2, 8.11.3.2 | 12 | 8.11.3.3 | 8.11.2.3, 8.11.3.4 | 60 | |
| 8.11.5.3 | Hand elevators | 8.11.2.1 | 12 | 8.11.2.2 | 12 | N/A | N/A | 8.11.2.3, 8.11.3.4 | 60 |
| 8.11.5.4 | Dumbwaiters | 8.11.2.1, 8.11.3.1 | 12 | 8.11.2.2, 8.11.3.2 | 12 | 8.11.3.3 | 8.11.2.3, 8.11.3.4 | 60 | |
| 8.11.5.5 | Material lifts and dumbwaiters with automatic transfer devices | 8.11.2.1, 8.11.3.1 | 12 | 8.11.2.2, 8.11.3.2 | 12 | 8.11.3.3 | 8.11.2.3, 8.11.3.4 | 60 | |
(History: Ord. No. PM-3289 §29, 2020)
Effective on: 1/1/1901