Title 18 - Unified Development Ordinance

 

18.435 Outdoor Lighting

 

18.435.090 Auto Dealer Lighting

 

  1. A.
    Lighting for automobile dealerships shall be limited to non-adjustable, vertical mount, precise cut-off fixtures with flat lenses mounted horizontally to grade. The maximum allowable height for light poles shall be 24 feet, including pole base. A lighting plan, including photometrics, shall be submitted as part of the final development plan. The permitted light levels are as follows:

 

 

Maximum average 

maintained

(footcandles) 

Maximum 

allowable

illuminance 

Average to

minimum ratio

(maximum) 

Maximum to

minimum ratio

(maximum) 

 Vehicle display areas 40 fc  50 fc  6:1  20:1 
 All other Vehicle Areas 5 fc  N/A  6:1  20:1 
  1. B.
    The maximum light temperature is 4000K.
  2. C.
    House side shields shall be provided on all perimeter parking lot lighting fixtures.

(History: Ord. No. ZRR-3447 §10, 2024)

Effective on: 1/1/1901