Title 18 - Unified Development Ordinance
18.435 Outdoor Lighting
18.435.050 Development and Performance Standards
Where provided, parking lot lighting, including building and pole mounted lighting is subject to the following standards:
-
A.Residential zoning listed below and all Non-Residential Uses in a Residential District.
| RP-2(R-2) | RP-3(R-3) | RP-4(R-4) | RP-5(R-5) | RP-6(R-6) | PRN (Multi-Family Uses) |
|---|
|
Maximum light temperature |
Maximum average footcandles |
Minimum average footcandles |
Average to minimum ratio |
Maximum to minimum ratio |
|---|---|---|---|---|
| 4000K | 2.0 | 1.0 | <6:1 | <20:1 |
-
-
1.Parking lot lighting mounting heights.
-
a.Maximum height of the pole and fixture shall be no taller than 20 feet when measured from grade. Measurement shall include the pole base.
-
-
-
B.Commercial and Industrial Uses
| CP-0(C-0) | CP-1(C-1) | CP-2(C-2) | CP-3(C-3) | MXD | DFD | BP |
MP-1 (M-1) |
MP-2 (M-2) |
|---|
|
Maximum light temperature |
Maximum average footcandles |
Minimum average footcandles |
Average to minimum ratio |
Maximum to minimum ratio |
|---|---|---|---|---|
| 4000K | 3.0 | 1.0 | <6:1 | <20:1 |
-
-
1.Parking lot lighting mounting heights.
-
a.Maximum height of the pole and fixture shall be no taller than 33 feet when measured from grade. Measurement shall include the pole base.
-
-
(History: Ord. No. ZRR-3447 §6, 2024)
Effective on: 1/1/1901